原装进口BXSN-8-PT168G滑
美国Catphan500CT性能测试
航空维修Astro工具 615708
ARO英格索兰Schlage门锁供应
产品展示 网站首页 > 产品中心
RSD 肺部/胸部模体,美国Radiology Support Devices (RSD)

产品编号:2013891606

产品描述:RSD 肺部/胸部模体

产品介绍


品名: RSD 肺部/胸部模体 英文名:RSD LUNG/ CHEST PHANTOMS 

厂家:Radiology Support Devices (美国RSD公司)


RSD LUNG/ CHEST PHANTOMS 

 

 

Lung/Chest with removable diaphragm and lung pair insert. 

 

Low Contrast & High Contrast 

  
 

The next best thing to human lungs for radiographic studies  

  • Extensive vascular detail 
  • Different degrees of vascular contrast 
  • Interchangeable normal and pathological lungs 

Developed in conjunction with the University of California at Irvine's Department of Radiological Sciences, the Alderson Lung/Chest Phantom is a specialized phantom, providing a high degree of realism in chest radiography.  

The Alderson Lung/Chest Phantom extends from the neck to below the diaphragm. It is molded about an RSD “Superhuman" male skeleton, corresponding to the external body size of a patient, 5'9" (175 cm) tall and weighing 162 lbs. (73.5 kg). RSD materials are equivalent to natural bone and soft-tissues. Animal lungs are selected to match the size of an adult male. Lungs are fixed in the inflated state and are molded to conform to the pleural cavities of the phantom. The pulmonary arteries are injected with a blood-equivalent plastic.  

The Lung/Chest Phantom with simulated left coronary artery reveals several areas of coronary artery irregularity and narrowing.  

To demonstrate different pathological conditions, five standard pathologies are available:  

1. Two contiguous 0.5 cm nodules at the tip of the first left rib.  

2. A 0.6 cm nodule superimposed with large vessel in the left lower lobe.  

3. A 1.5 cm nodule, left mediastinal shadow.  

4. A 0.6 cm nodule blending in with the right pulmonary artery.  

5. Pneumonia in the right lower lobe.  

(Custom pathologies are available upon request)  

The Lung/Chest Phantom is available either with the diaphragm permanently sealed to the interior of the phantom, fixing the lungs in place, or with a removable diaphragm, which permits the interchange of lungs, and provides an unlimited number of configurations and disease simulations. All models are available with blood-equivalent pulmonary arteries, or with low or high contrast media added. 

 


 

Lung / Chest Phantoms model numbers。 RSD模体订货型号

RS-310 Lung/Chest Phantom with permanently sealed diaphragm

RS-315 Lung/Chest Phantom with permanently sealed diaphragm and left coronary artery

RS-320 Lung/Chest Phantom with removable diaphragm lung pair insert without coronary artery

RS-330 Lung/Chest Phantom with removable diaphragm lung pair insert with coronary artery

RS-340 Lung/Pair insert without coronary artery

RS-345 Lung/Pair insert with coronary artery

友情链接: 进口代理  |   纽智鹏  |   香港贸易  |   美国进口  |   湾边贸易  |  
  CopyRight 2023 Coast Hongkong Limited. All Rights Reserved,  粤ICP备11054825号-7
  地址:UNIT 83 3/F YAU LEE CENTERNO.45 HOI YUEN ROAD KWUN TONG, KL, HONGKONG 电话:0755-86216601 传真:0755-86216602